EMC Technologies Home Page Accredited by NATA .... Company History & Archives Seminars & Training EMR RadHaz - measurement, predictions & modelling Site Map - Table of Contents Electrical Safety EMC Technologies Home Page Electrical Safety Technical Articles & External Links Company History & Archives
The Site Management Alliance  provides an integrated EMR management solution.

 


 

Up

Melbourne Branch's NATA Accreditations:


EMC Technologies Pty. Ltd. is accredited by the National Association of Testing Authorities (NATA). Australia.   NATA has mutual recognition agreements (MRA) with over 30 similar accreditation bodies around the world including NVLAP, A2LA, UKAS, DaTech.   The MRA facilitates acceptance and recognition of NATA endorsed reports in most countries.


Table of Contents:


A NATA endorsed reports means that you only need test once and your product can be sold in global markets.

NATA logo NATA Accredited Laboratory Number: 5292

EMC Technologies Pty Ltd is NATA accredited for  a wide range of EMC, EMR, SAR and Safety standards.  

EMC Technologies Melbourne Branch  Testing accreditations include;

Emissions

AS/NZS 3548 (obsolete) replaced with AS/NZS CISPR22, EN55022 ITE
AS/NZS 2064 (obsolete) replaced with AS/NZS CISPR11, EN55011  ISM
AS/NZS 2557 (obsolete) replaced with AS/NZS CISPR 12. EN55012
AS/NZS1044 (obsolete) replaced with AS/NZS CISPR14.1, EN55014-1  Appliances
AS/NZS1053 (obsolete) replaced with AS/NZS CISPR13
AS/NZS 4051 (obsolete) replaced with AS/NZS CISPR 15
AS/NZS 4251.1 and EN 55081.1 Generic  (obsolete) both repalced with EN61000-6-3
FCC Part 15 requirements and ANSI C63.4 for unintentional and intentional emitters in the frequency range 9 kHz to 18 GHz excluding TV receivers (15.117 and 15.119), TV interface devices (15.115), cable ready consumer electronic equipment (15.118), cable locating equipment (15.213), unlicensed national information infrasture devices (Sub part E), unlicensed PCS devices (Sub part D) and ultra wideband operation (Sub part F)
FCC Part 18 requirements and ANSI C63.4 for intentional emitters up to 18 GHz
Measurement of conducted emissions on electrical equipment for compliance with the requirements of MIL-STD-461 in accordance with the following MIL-STD-462 methods:CE01, CE101, CE03, CE102
Measurement of radiated emissions from electrical equipment for compliance with the requirements of MIL-STD-461 in accordance with the following MIL-STD-462 methods: RE01, RE101, RE102 (from 10 kHz to 1 GHz) RE02 (from 14 kHz to 1 GHz)
AS/NZS4251.1, EN50081-1, EN61000-6-2 Generic

top of page

Immunity

IEC 61000-4-2, EN 61000-4-2 Electrostatic Discharge (ESD) [IEC 801-2]
AS/NZS 61000-4-3, IEC 61000-4-3, EN 61000-4-3  Radiated RF interference [IEC 801-3]
IEC 61000-4-4, EN 61000-4-4 Electrical Fast Transient Bursts (EFT/B) [IEC 801-4]
AS/NZS 61000-4-5, IEC 61000-4-5, EN 61000-4-5 Surges 
AS/NZS 61000-4-6, IEC 1000-4-6, EN 61000-4-6 RF conducted disturbances 
IEC 61000-4-8, EN 61000-4-8 Mains frequency magnetic fields
IEC 61000-4-11, EN 61000-4-11 Voltage dips, short interruptions and voltage variations
Immunity tests in accordance with NSC publication for Pattern Approval and Initial Verification of Electricity Meters and Associated Transformers - 1999
Performance of conducted susceptibility tests on electrical equipment for compliance with the requirements of MIL-STD-461 in accordance with the following MIL-STD-462 methods:  CS01, CS101, CS02 (except broadband susceptibility to Notice 3), CS06, CS114 (curves 1 to 4 only), CS115
Performance of radiated susceptibility tests on electrical equipment for compliance with the requirements of MIL-STD-461 in accordance with the following MIL-STD-462 methods: RS01, RS02, RS03, RS101 and RS103 (up to 20 V/m from 1 to 18 GHz and 20 to 50 V/m from 10 kHz to 1 GHz)

top of page

RF and microwave radiation hazard measurement

Measurement of electromagnetic fields in accordance with AS 2772.2 and EMC Technologies TP2772 Revision 2.x for compliance with APRANSA Radiation Protection Standard (RPS No.3) and AS/NZS 2772.1 (Int):1998; Broadband measurements of E-fields in the range 100 kHz to 45.5 GHz Broadband measurements of H-fields in the range 100 kHz to 1 GHz Narrowband measurements of E-fields in the range 9 kHz to 18 GHz with least uncertainties of measurement of - 3 dB
 
SAR Measurement
ACA - Electromagnetic Radiation Human Exposure Standard: 2003
FCC - Guidelines for Human Exposure to RF Electromagnetic Field: 1997
CENELEC - ES 59005: 1998
EN 50360: 2001
EN 50361: 2001
IEEE 1528: 2003

top of page

RF Shielding Effectiveness

Attenuation performance tests on shielded enclosures in accordance with MIL-STD-285 Rev 1.1

top of page


Refer to the NATA website for the full scope of EMC Technologies accreditations.

top of page



 

EMC Technologies Logo; Click to go to Home Page

If it's really URGENT

Call any time on: +61 418 566 466 

EMC Technologies - Victoria (Head Office)

176 Harrick Road Keilor Park Victoria 3042 Australia
Ph: +61 3 9365 1000          Fax: +61 3 9
331 7455

 

EMC Technologies -  New Zealand

47 MacKelvie Street, Grey Lynn, Auckland New Zealand         Ph: + 64 93600 862       Fax: + 64 93600 861

 

EMC Technologies - New South Wales

Unit 3, 87 Station Road, Seven Hills NSW 2147 Australia                Ph: + 612 9624 2777       Fax:  + 612 9838 4050

 

EMC Technologies - Queensland

Unit 1 / 15 Success Street, Acacia Ridge 4110 Qld Australia    Ph: + 617 3875 2455       Fax: + 617 3875 2466


www.emctech.com.au